Get more from your source
|
|
|
Viking Flow Dividers split a fluid flow into two, three, or four equal streams, regardless of differing pressures. These flow dividers are used for a variety of fluid power applications, such as eliminating the need for multiple pumps, and synchronizing hydraulic cylinders. Anti-friction needle bearings, precision ground heat-treated steel
gears and case-hardened steel shafts ensure maximum operating life. SAE O-ring porting is standard.
|
| Capacity |
0 - 11 m³/hr |
0 - 50 GPM |
| Pressure |
0 - 240 BAR (at outlet) |
0 - 3500 PSI (at outlet) |
| Viscosity |
30 cSt Hydraulic Oil |
150 SSU Hydraulic Oil |
| Temperature |
-40 - 105 C |
-40 - 225 F |
|
Specifications
|
Model
|
No. of Sections
(outlet ports)
|
Displacement Per Section
|
Inlet Flow Range
|
Maximum Pressure (Cont.)*
|
|
cm³/rev
|
in³/rev
|
LPM
|
GPM
|
BAR
|
PSI
|
|
GD-05BB00-GV
|
2
|
2.27
|
0.139
|
3.8 - 18.9
|
1 - 5
|
103 (103)
|
1500 (1500)
|
|
GD-05BB00-GO
|
2
|
2.27
|
0.139
|
3.8 - 18.9
|
1 - 5
|
207 (207)
|
3000 (3000)
|
|
GD-05BBB0-GV
|
3
|
2.27
|
0.139
|
5.6 - 28.3
|
1.5 - 7.5
|
103 (103)
|
1500 (1500)
|
|
GD-05BBB0-GO
|
3
|
2.27
|
0.139
|
5.6 - 28.3
|
1.5 - 7.5
|
207 (207)
|
3000 (3000)
|
|
GD-05BBBB-GV
|
4
|
2.27
|
0.139
|
7.5 - 38.7
|
2 - 10
|
103 (103)
|
1500 (1500)
|
|
GD-05BBBB-GO
|
4
|
2.27
|
0.139
|
7.5 - 38.7
|
2 - 10
|
207 (207)
|
3000 (3000)
|
|
GD-05EE00-GV
|
2
|
6.36
|
0.388
|
11 - 53
|
3 - 14
|
103 (83)
|
1500 (1200)
|
|
GD-05EE00-GO
|
2
|
6.36
|
0.388
|
11 - 53
|
3 - 14
|
166 (83)
|
2400 (1200)
|
|
GD-05EEE0-GV
|
3
|
6.36
|
0.388
|
17 - 68
|
4.5 - 18
|
103 (83)
|
1500 (1200)
|
|
GD-05EEE0-GO
|
3
|
6.36
|
0.388
|
17 - 68
|
4.5 - 18
|
166 (83)
|
2400 (1200)
|
|
GD-05EEEE-GV
|
4
|
6.36
|
0.388
|
23 - 68
|
6 - 18
|
103 (83)
|
1500 (1200)
|
|
GD-05EEEE-GO
|
4
|
6.36
|
0.388
|
23 - 68
|
6 - 18
|
166 (83)
|
2400 (1200)
|
|
GD-07BB00-GV
|
2
|
12.53
|
0.765
|
23 - 95
|
6 - 25
|
103 (103)
|
1500 (1500)
|
|
GD-07BB00-GO
|
2
|
12.53
|
0.765
|
23 - 95
|
6 - 25
|
207 (172)
|
3000 (2500)
|
|
GD-07BBB0-GV
|
3
|
12.53
|
0.765
|
34 - 142
|
9 - 37.5
|
103 (103)
|
1500 (1500)
|
|
GD-07BBB0-GO
|
3
|
12.53
|
0.765
|
34 - 142
|
9 - 37.5
|
207 (172)
|
3000 (2500)
|
|
GD-07BBBB-GV
|
4
|
12.53
|
0.765
|
45 - 189
|
12 - 50
|
103 (103)
|
1500 (1500)
|
|
GD-07BBBB-GO
|
4
|
12.53
|
0.765
|
45 - 189
|
12 - 50
|
207 (172)
|
3000 (2500)
|
|
GD-07DD00-GV
|
2
|
25.07
|
1.530
|
45 - 189
|
12 - 50
|
103 (86)
|
1500 (1250)
|
|
GD-07DD00-GO
|
2
|
25.07
|
1.530
|
45 - 189
|
12 - 50
|
172 (86)
|
2500 (1250)
|
|
GD-07DDD0-GV
|
3
|
25.07
|
1.530
|
68 - 284
|
18 - 75
|
103 (86)
|
1500 (1250)
|
|
GD-07DDD0-GO
|
3
|
25.07
|
1.530
|
68 - 284
|
18 - 75
|
172 (86)
|
2500 (1250)
|
|
GD-07DDDD-GV
|
4
|
25.07
|
1.530
|
91 - 284
|
24 - 75
|
103 (86)
|
1500 (1250)
|
|
GD-07DDDD-GO
|
4
|
25.07
|
1.530
|
91 - 284
|
24 - 75
|
172 (86)
|
2500 (1250)
|
* Maximum Pressure Differential Between Sections for Intermittent Duty (Continuous Duty Pressure Shown in Parentheses). Slip per Section in GPM/100 PSI is 0.010 for 05B, 0.034 for 05E, 0.045 for 07B, and 0.060 for 07E.